Duty chartKVCE 35-120 MCE MY13Performance curveKVCE 35-120MotorMakeDABMain category1~ motorMotor design1 PH DM STDFrequency, poles50 Hz - 2 polesMotorIE3 MCE15/P - 1.10 2p - KVCE 35/120 M (1,1 kW)Degree of protectionIP 55Type of protection--Electrical connection230 VType of installationNameElectronic vertical axis pumpsMaterial combinationMaterial combinationKVC nuoveImpellerTechnoplymer BDiffuserTechnoplymer BShaft with rotorAISI 303 X10 CrNiS 1809 UNI 6900/71Mechanical sealSilicon carbide/CarbonExternal sleeveAISI 304 X5 Cr Ni 1810 UNI 6900/71Seal diskAISI 304 X5 Cr Ni 1810 UNI 6900/71O-RingEPDM RubberPump bodyTechnopolymer AIntermediate stageTechnoplymer BDiffuser bodyTechnoplymer BCentering bushingBronze B14ConveyorTechnoplymer BPipe connectionsInlet/Outlet1 " 1/4 GFlange standardPN/DNPressure rating12 bar (1200 KPa)Nominal pipe size1 " 1/4 G



' />
KVCE 35-120 M MCE11/P IE3 KVCE 35-120 M MCE11/P IE3 KVCE 35-120 M MCE11/P IE3 KVCE 35-120 M MCE11/P IE3 KVCE 35-120 M MCE11/P IE3

KVCE 35-120 M MCE11/P IE3

Varenr: 60201915

TECHNICAL DATA
Operating range: from 1 to 12 m3/h with head up to 110 metres.
Pumped liquid: clean, free of solids and abrasives, non-viscous, non crystallised and chemically neutral, with properties similar to water.
Liquid temperature range:
from 0 °C to +35 °C for domestic use (EN 60335-2-41 safety standards).
from 0 °C to +40 °C for other uses.
Maximum ambient temperature: +40 °C.
Maximum operating pressure: 12 bar (1200 kPa).
Installation: fixed, vertical position.

APPLICATIONS
Vertical multistage centrifugal pump suitable for medium to large user water systems. Recommended for pressurisation units, boiler supply, hot water and cooling water circulation, fire fighting and washing systems, drinking water supply and filling of pressure vessels, sprinkler and watering systems and water purification systems.
ADVANTAGES OF USE
Operating pressure stability - Excellent energy saving (up to 60 % ) - Reduced hammering effects - Reduced space requirements - Less maintenance - Reduced pump wear - Less power factor correction required - Less water consumption -
Integrated protections.
CONSTRUCTION FEATURES OF THE PUMP
Technopolymer delivery and suction bodies with IN-LINE suction and delivery ports with threaded metal insert.
Impellers, diffuser bodies and diffusers in technopolymer, fully rust-proof.
AISI 304 stainless steel pump liner, adjustment rings and seal disc. Carbon/ceramic mechanical seal, fitted on the AISI 303 stainless-steel drive shaft extension.
CONSTRUCTION FEATURES OF THE MOTOR
Shaft with rotor running on permanently lubricated ball bearings, oversized to ensure low noise and durability.
Construction according to CEI 2-3.
Controlled by MCE inverter.
Protection class: IP 55
Insulation class: F.
Standard single-phase voltage: 1x230 V / 50-60 Hz
Special version on request: three-phase 3x400 V / 50 Hz, or three-phase 3x460 V / 60 Hz
Standard three-phase voltage: 3x400 V / 50 Hz
Special version on request: 3x460 V / 60 Hz

MCE/P INVERTER
CONSTRUCTION FEATURES OF THE ELECTRONICS: MCE/P INVERTER
The inverter continuously adjusts the rotation speed of the electric pump, keeping the pressure constant, even when the flow rate varies.
The other electric pumps, also with variable speed, are activated in cascade after the first one has reached maximum speed. Through modulation, they compensate the pressure fluctuations of the system.
For every operating cycle, it is possible to switch the restart to a different pump, therefore ensuring even use of all electric pumps.
It is possible to set operation times for each individual pump, switching to another pump after such set times.
The "SP" pressure can be adjusted by the user using the "+" and "-" keys found on the MCE/P (as a rule, all the pumps are set to the same pressure value). With the new MCE/P, it is sufficient to set the data on one of the devices, and it will be automatically propagated to the other pumps of the system.

 

 

Hydraulic selection
Duty chartKVCE 35-120 MCE MY13
Performance curveKVCE 35-120
Motor
MakeDAB
Main category1~ motor
Motor design1 PH DM STD
Frequency, poles50 Hz - 2 poles
MotorIE3 MCE15/P - 1.10 2p - KVCE 35/120 M (1,1 kW)
Degree of protectionIP 55
Type of protection--
Electrical connection230 V
Type of installation
NameElectronic vertical axis pumps
Material combination
Material combinationKVC nuove
ImpellerTechnoplymer B
DiffuserTechnoplymer B
Shaft with rotorAISI 303 X10 CrNiS 1809 UNI 6900/71
Mechanical sealSilicon carbide/Carbon
External sleeveAISI 304 X5 Cr Ni 1810 UNI 6900/71
Seal diskAISI 304 X5 Cr Ni 1810 UNI 6900/71
O-RingEPDM Rubber
Pump bodyTechnopolymer A
Intermediate stageTechnoplymer B
Diffuser bodyTechnoplymer B
Centering bushingBronze B14
ConveyorTechnoplymer B
Pipe connections
Inlet/Outlet1 " 1/4 G
Flange standardPN/DN
Pressure rating12 bar (1200 KPa)
Nominal pipe size1 " 1/4 G





58612